15kV European 630/1250A Unshielded Detachable Connector
15kV European 630/1250A Unshielded Detachable Connector
Couldn't load pickup availability
Application areas:
Used for cable entry and exit points in high-voltage electrical equipment. Type "C" bushings conforming to EN 50180 & EN 50181 standards provide electrical connection between the bushing and the cable.
Product Description
The 15kV European 630/1250A unshielded separable connector includes: a 15kV unshielded European front connector, a 15kV unshielded European rear connector, a WEQπ-15/630-3×□-17/45 unshielded front connector for angled π surge arresters, and a WEHπ-15/630-3×□-17/45 unshielded rear connector for angled π surge arresters.
When in operation, the unshielded front-mounted cable is bolted to the switchgear bushing socket; its tail can be directly plugged with an insulating plug, or it can be extended to connect to unshielded rear-mounted cable plugs, unshielded rear-mounted surge arresters, or unshielded rear-mounted inclined π surge arresters. The product conforms to the C-type bushing design in standards EN 50180 & 50181.
When the unshielded front-connected π surge arrester is in operation, it is bolted to the bushing socket of the switchgear, and the tail is directly plugged with an insulating plug. It cannot be extended further.
Unshielded rear-mounted cable plugs, unshielded rear-mounted surge arresters, and unshielded rear-mounted inclined π surge arresters can only be used with unshielded front-mounted plugs and cannot be used interchangeably with shielded plugs.



-
Product Parameters
Electrical performance of front and rear plugs:
Rated voltage 15kV Applicable sleeve type (front insertion) Type C AC withstand voltage 39kV/5min Partial discharge 15kV, ≤10pC Impulse voltage (10 times each for positive and negative polarities) 95kV Applicable cable cross-section 25-630mm2 Note: This product meets the requirements of IEC 60502.4 and GB/T 12706.4. Surge arrester electrical performance:
Serial Number project unit parameter 1 Product Model - YH5WS-17/50 YH5WZ-17/45 HY5WZ-17/45 YH5WR-17/45 YH5WZ-10/27 YH5WS-10/30 YH5WS-13/36 2 System nominal voltage kV 10 10 10 10 6 6 10 3 Surge arrester rated voltage kV 17 17 17 17 10 10 13 4 Continuous operating voltage kV 13.6 13.6 13.6 13.6 8.0 8.0 10.4 5 Nominal discharge current In kA 5 5 5 5 5 5 5 6 DC 1mA reference voltage kV ≥25 ≥24 ≥24 ≥24 ≥14.4 ≥15 ≥19.3 7 0.75U1mA leakage current μA ≤10 ≤10 ≤10 ≤10 ≤10 ≤10 ≤10 8 steep wave impact residue kV ≤57.5 ≤51.8 ≤51.8 ≤51.8 ≤31 ≤34.6 ≤41.3 9 Lightning impact residual pressure kV ≤50 ≤45 ≤45 ≤45 ≤27 ≤30 ≤36 10 Operating impact residual pressure kV ≤42.5 ≤35 ≤38.3 ≤38.3 ≤23 ≤25.6 ≤30.7 11 Partial discharge at 14.3kV pC ≤10 ≤10 ≤10 ≤10 ≤10 ≤10 ≤10 12 2ms square wave impulse current withstand A 100 200 200 400 150 75 150 13 High current surge withstand kA 65 65 80 65 65 65 65 Wolong Electric is committed to continuous product improvement, therefore we reserve the right to change designs, dimensions, and data without prior notice.