30kV heat shrink joint

30kV heat shrink joint

Regular price 0₫
Regular price Sale price 0₫
Sale Sold out

Application areas:

Intermediate processing for 30kV cross-linked cables

Product Description

a . Many cable joint failures are caused by poor sealing. Our company uses a new process (three-layer sealing process) to make the cable safer and more reliable in operation. The so-called three-layer sealing refers to the outer sheath sealing, the inner sheath sealing, and the sealing at both ends of the inner insulation tube, for a total of three seals.

b . The insulation tube was lengthened, which solved the creepage problem.

c . The sheath is flexible and flame-retardant.

Product Parameters

Serial Number

Test Item 1 )

Standard requirements

Indoor

outdoor

middle

1

Power frequency withstand voltage test

81kV , 5min

Power frequency withstand voltage test under rain

------

At 72kV , for 1 minute, the combined sample did not exhibit flashover or breakdown.

------

2

Partial discharge test at room temperature

------

The discharge quantity of the combined sample at 30kV is ≤10pC.

------

3

High-temperature impulse voltage test, under θ t 2)

170kV , 10 positive and 10 negative polarity impacts without flashover or breakdown.

6

Constant pressure load cyclic test (in air)

Cycling 60 times at θt temperature and 45kV .

7

Partial discharge (at θt2 ) 4 ) and ambient temperature t )

≤10pC at 30kV

8

Short -circuit thermal stability (shielded 5 )

Under the I SC shielding of the cable , two short circuits resulted in no visible damage;

9

Short-circuit thermal stability (conductor)

When the conductor temperature is raised to θ SC , two short circuits occur without visible damage.

10

Impulse voltage test

10 impacts per polarity

11

AC withstand voltage

45kV , 15min

12

Humidity test

22.5kV , 300

        ------            ------

13

Salt spray test

------

22.5kV , 1000H         ------

1) Unless otherwise specified, the test shall be conducted at ambient temperature;

2) θt is the highest temperature of the conductor during normal operation plus ( 5-10 ) ;

3) Each cycle lasts 8 hours , with a temperature stabilization time of at least 2 hours and a cooling time of at least 3 hours ;

4) Take measurements at the end of the heating period;

5) This test is only applicable to terminals that can be directly or indirectly connected to the cable's metal shield via a bushing;

Product Selection

voltage level

Number of wire cores

Cable cross-section /mm2

Product Code

18/30 ( 36 ) kV

19/33 ( 36 ) kV

3,1

35-50

70-120

150-240

300-400

500-630

18/30kVRSJY-3/1(1/1)

18/30kVRSJY-3/2(1/2)

18/30kVRSJY-3/3(1/3)

18/30kVRSJY-3/4(1/4)

18/30kVRSJY-3/5(1/5)

View full details